/themes/my_demo/public/assets/images/s24w1.png

CP900

CP900_01.jpgCP900_02.jpgCP900_03.gifCP900_04.jpgCP900_05.jpg

- Supports 802.11ac Wave2 technology with Qualcomm Atheros chipsets.

- Delivers up to 867Mbps wireless speeds on 5G band.

- MU-MIMO technology allows multiple devices data transfer simultaneously.

- Built-in 12dBi dual polarized antennas ensure reliable Wi-Fi connection.

- Watchdog hardware design for easy troubleshooting automatically.

- Passive PoE power supply with up to 100m power transmission.

- IP65 level dustproof and waterproof for professional structural design.

- 6KV lighting proof and 15KV ESD is resilient to all harsh environments.

- 4 intelligent LED indicators intuitively show signal strength.

- Provides AP/Client/Repeater/WISP working modes.


Hardware

Processor

- Qualcomm Atheros 560MHz CPU

Memory

- 128MB DDR2 RAM, 16MB Flash

Interface

- 1 *100BaseTX (Auto MDI/MDIX) LAN Port 

- 1 *GND SMA connector

Power Supply

- 24V/1A(POE)

-  Voltage range: 12-24VDC

Button

- 1 *RESET Button

Antenna

- Built-in 12dBi dual polarized antennas

LED Indicators

- 1 *Power,

- 1 *LAN,

- 4 *Signal Strength

Dimensions(L X W X H)

- 237.5 x 79 x 58.5mm

Wireless

Wireless standard

- IEEE 802.11ac

- IEEE 802.11n

- IEEE 802.11a

RF Frequency

- 5.15~5.85GHz
Data Rate

- Up to 867Mbps

EIR

  < 23dBm

Wireless Security

- 64/128-bit WEP, WPA/WPA2, WPA-PSK/WPA2-PSK (TKIP/AES)

Reception Sensitivity

- 11n(HT20): -68 dBm@10% PER

- 11n(HT40): -65 dBm@10% PER

- 11a: -72 dBm@10% PER

- 11ac(VHT80): -55 dBm@10% PER

Software

Operation Mode

- Access Point

- Repeater Mode

- Client Mode

- WISP Mode

Network

- LAN Setting

- WAN Setup (WISP Mode only)

Wireless

- Basic Setting, 

- MAC Authentication, 

- Advanced Setting, 

- Wireless Schedule, 

- VLAN Tag(AP Mode only), 

- WMM

Firewall  

- IP/Port Filtering, 

- MAC Filtering, 

- URL Filtering, 

- Port Forwarding, 

- DMZ

Management

- Administrator Setting, 

- Time Setting, 

- Upgrade Firmware, 

- System Configuration, 

- System Log, 

- Reboot Schedule, 

- Logout

Reliability

- 6KV Lightning Protection

- 15KV ESD Protection

- IP65 level dustproof and waterproof

Circuit

- Watch-dog circuit

Others

Package Contents

- CP900 Wireless CPE *1

- PoE Box *1

- Power Adapter *1

- User Guide *1

- Ethernet Cable *1

- Strips*2

Environment

- Operating Temperature: -40℃~70℃ (-40 ℉~158℉)

- Storage Temperature: -40℃~70 ℃ (-40 ℉~158℉)

- Operating Humidity: 5%~95% non-condensing

- Storage Humidity: 5%~95% non-condensing

  • 1

No

Title

Views
1

What if the CPE can't log in to the new Chrome?

468

     It is suitable for: All TOTOLINK CPE

Application introduction 

After entering the management address of the CPE in the address bar of Chrome browser, the page cannot be displayed after entering the management password, as shown below.

Note: Ensure that the login IP address you typed in the address bar is correct, as well as the login username and password. 

1.png


 Set up steps 

STEP-1: Change browser and clear browser cache

Try changing old version (before 72.0.3626.96) of Chrome browser or try other browser, such as Firefox, Internet Explorer, etc., and clear your browser cache. 2.png

Delete cookies on the web browser. Here we take Firefox for example.

Note: In general, the browser enters the management address of the CPE and error pops up. Please use this method first.

图片1.png 

STEP-2: Take CP900 as an example

2-1. CP900 default Gateway IP address 192.168.0.254:

Assigned manually IP address 192.168.0.x “x” range from 2 to 253, the Subnet Mask is 255.255.255.0 and Gateway is 192.168.0.254.

3.png 

2-2. Enter 192.168.0.254 into the address bar of your browser. Log in the settings interface.

4.png 

[Note]: 

The default access address varies depending on the actual situation. Please find it on the bottom label of the product.

2

How to properly download upgrade firmware of CPE?

605

     It is suitable for: All TOTOLINK CPE

 Preparation 

Before downloading files. please confirm the hardware version ofyour device and choose the corresponiding firmware version to uparade. 

Wrong firrmware version may damage your device and no warrante.


 Set up steps 

STEP-1: Guide for Hardware Version

For most TOTOLINK CPE, you can see two bar coded stickers at the front of the device, the character string started with Model No.(for example CP300) and ended with hardware Version (for example V2.0) is the serial number of your device. See below:


1.png 

STEP-2:

Open browser, enter www.totolink.net Download the required files.

For example, if your hardware version is V2.0 , please download V2 version.

Note: If the hardware version is V1, V1 will be hidden.

2.png 

 

STEP-3:

Unzip the file, correct upgrade file name is suffixed with ”web” or “bin” (except for some special models)

3.png

3

How to log in CP900's setting interface

1211

    Application introduction    

If you want to login to CP900’s setting interface to configure some settings, please follow the steps below.

    It is suitable for:  CP900_V1    


STEP-1:

1-1. Connect your computer to the router by cable or wireless


1-2. Setup you PC to get the IP automatically (Here I take system W10 for example)


1-3. Click on 1.png at the bottom right corner on the screen

2.png

1-4. Click [Properties] button in the lower left corner

3.png

1-5. Double click on “Internet Protocol (TCP/IP)”.

4.png


STEP-2:

Now you have two ways to configure the TCP/IP protocol below

2-1. Use the first default IP address 192.168.0.254:

Assigned manually IP address 192.168.0.x “x” range from 2 to 253, the Subnet Mask is 255.255.255.0 and Gateway is 192.168.0.254.

5.png

Enter 192.168.0.254 into the address bar of your browser. Log in the settings interface.

图片1.png


[Note]: 

192.168.0.254 can only be used in AP mode and WISP mode; Client mode and Repeater mode please use his second IP address 169.254.0.254.

 

2-2. Use the second IP address 169.254.0.254:

Assigned manually IP address 169.254.0.x “x” range from 2 to 253, the Subnet Mask is 255.255.255.0 and Gateway is 169.254.0.254.

7.png


Enter 169.254.0.254 into the address bar of your browser. Log in the settings interface.

8.png



[Note]: 

169.254.0.254 supports login in Client mode, Repeater mode, AP mode and WISP mode.

 

STEP-3:

After the setup is successful, your computer must choose to obtain an IP address automatically to access the network. As the picture shows.

9.png

4

How to Select Operation Mode of CPE Products

829

    Application introduction    

This document describes the characteristics and application scenarios of different modes supported by TOTOLINK CPE, including Client mode, Repeater mode, AP mode and WISP mode.

    It is suitable for:  CP900_V1    

STEP-1: Client mode

Client mode is used to transfer wireless connection into wired connection. In Client mode, the device serves as a wireless adapter. It receives the wireless signal from root AP or station, and provides wired network for users.

Scenario 1:

1.png

Scenario 2:

2.png

STEP-2: Repeater mode

Repeater Mode In this mode,you can extend the superior Wi-Fi signal by Repeater setting function under the Wireless column to increase the coverage of the wireless signal.

Scenario 1:

3.png

Scenario 2:

4.png

STEP-3: AP mode

AP mode connect the superior AP/Router by wire, you can transfer the superior's AP/Router wired signal into wireless signal.

 

Scenario 1:

5.png

Scenario 2:

6.png

Scenario 3:

7.png

Scenario 4:

8.png


STEP-4: WISP Mode

WISP Mode In this mode, all ethernet ports are bridged together and the wireless client will connect to ISP access point. The NAT is enabled and PCs in ethernet ports share the same IP to ISP through wireless LAN.

Scenario 1:

9.png



    FAQ Common problem    

Q1: How to reset the CPE to factory default Settings?

Keep the CPE powered on, press the RESET button on CPE or Passive PoE box about 8 seconds, the CPE will restore to factory default settings.

10.png


Q2: What Can I do If I forgot the CPE’s Web Login User Name and Password?

In case you changed your CPE’s Login User Name and Password, we suggest you reset your CPE to factory default settings by above operations. Then use the following parameters to login the CPE’s Web interface:

Default IP address: 192.168.0.254

User Name: admin

Password: admin